SBC MT 01 Especificaciones Pagina 74

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 132
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 73
GROUP S.P.A.
MT SBC 01
72
Standard function: Privacy
This function enables you to set the Privacy function on the
pushbutton. If enabled, it allows you to disable temporarily the
ringtone of the interphone in response to calls from the external
unit and porter switchboard Art. 1998A.
The landing call and intercom call ringtones are not disabled.
To enable or disable the Privacy function, press the monitor or
interphone pushbutton on which the function has been
programmed for 2 seconds; selection of the enabled state is
also indicated by the illumination of the indicator LED.
The function does not require the programming of any
Parameter.
Standard function: Doctor
This function enables you to set the Doctor function on the
pushbutton.
Enablement is also indicated by the signalling LED lighting up.
When there are several users with the same user code, set the
Doctor function on only one of the units enabled for this.
To enable or disable the Doctor function, press the monitor or
interphone pushbutton on which the function has been
programmed for 2 seconds; selection of the enabled state is
also indicated by the illumination of the indicator LED.
The function does not require the programming of any
Parameter.
Standard function: Intercom
This function enables you to set the intercom call function on
the pushbutton.
The function is available only for intercom systems that use
internal extensions Art. 4897, 5714CI, 4784I, 2618 and 2418W.
Group Intercom
This function enables you to set the group intercom call
function on the pushbutton.
The function is available only for intercom systems that use
internal extensions Art. 4897, 5714CI, 4784I, 2618 and 2418W.
Function
[Coded Actuator.]
PARAMETER
35
Fig. 19
Internal extension common programming
operations
The paragraphs below describe programming operations which are
common to all programmable internal extensions Art. 4897, 5714C,
5714CI, 4784, 4784I, 2618 and 2418W.
How to assign a standard function to a pushbutton
To programme a pushbutton you must:
1. Connect the hand-held programmer to the device to be
programmed, see page 68.
2. Use the and keys to select the Prog. Pushbuttons
menu and then press .
3. Use the and keys to select the pushbutton that you
want to programme and then press .
4. Use the and keys to select Standard Func., and
then press .
5. Using the and keys, scroll through the available
functions until the display shows the function you want to
programme on the pushbutton.
6. If necessary, go the to parameter field using and and
enter the requested numerical value (see standard functions
description on page 71) using the keypad of the programmer.
7. Press and make sure that the following message
appears:
-
-
If the operation is not successful, the display will show the
message:
-
If the operation is not permitted, the display will show an error
message . Setting a remote camera on a
secondary bracket/monitor is incompatible and therefore not
permitted.
8. After a few seconds the display shows the pushbutton selection
menu for any further operations on the extension.
EXAMPLE: setting Actuator with code 35 on pushbutton 2 of the
monitor.
“Oper. failed!”
“Transm. failed!”
“Operation OK”
“Transmission OK”
Ok
Sel
Sel
Sel
Art. 5714C
Connection OK!
—————————
Prog. pushbuttons
Read pushbuttons
Pushbutton 1
Pushbutton 2
Pushbutton 3
Reset pushbutton
Standard Func.
Camera cycle
Function:
Coded Actuator
parameter
[ ]
OPERATION DISPLAY
Connect hand-held programmer
Art. 1251/A to bracket 5714C.
Select Prog. Pushbuttons and
press .
Select Pushbutton 2 and press
.
Select Standard. Func. and press
.
Use the and
keys to scroll the Coded
Actuator function.
Sel
Sel
Sel
Vista de pagina 73